<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="el-observation-finalrefraction" />
  <url value="http://fhir.essilorluxottica.com/fhir/StructureDefinition/el-observation-finalrefraction" />
  <version value="1.0.0" />
  <name value="ELFinalRefraction" />
  <title value="EL Final Refraction Profile" />
  <status value="draft" />
  <description value="The EL Final Refraction Profile inherits from Observation resource. The profile contains all the elements in the Final Refraction section in the VisionX EHR application. A single instance captures refraction, visual acuities and pupillary distances for OD or OS, or visual acuities and pupillary distances if bodySite is OU." />
  <fhirVersion value="4.0.1" />
  <kind value="resource" />
  <abstract value="false" />
  <type value="Observation" />
  <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Observation" />
  <derivation value="constraint" />
  <differential>
    <element id="Observation">
      <path value="Observation" />
      <constraint>
        <key value="eyecondition-requires-no-measurements" />
        <severity value="error" />
        <human value="OD/OS - if an eye condition exists there cannot be any measurements." />
        <expression value="(bodySite.coding.where( code = 'od' or code = 'os' ).exists()) and&#xA;      component.value.coding.where( code = 'nolens').exists() or&#xA;      component.value.coding.where( code = 'balance').exists() or&#xA;      component.value.coding.where( code = 'prosthesis').exists()&#xA;   implies&#xA;      component.code.coding.where( code != 'eyeCondition' and code != 'diopterIncrement' and code != 'wearschedule' and code != '98908-7' and code != 'ophthalmoscopyMethod' ).exists().not()" />
        <source value="http://fhir.essilorluxottica.com/fhir/StructureDefinition/el-observation-finalrefraction" />
      </constraint>
      <constraint>
        <key value="no-eyecondition-requires-measurements" />
        <severity value="error" />
        <human value="OD/OS - if no eye condition exists there must be measurements." />
        <expression value="(bodySite.coding.where( code = 'od' or code = 'os' ).exists()) and&#xA;      component.value.coding.where( code = 'eyeCondition' ).exists().not() and&#xA;      component.value.coding.where( code = 'nolens').exists().not() and&#xA;      component.value.coding.where( code = 'balance').exists().not() and&#xA;      component.value.coding.where( code = 'prosthesis').exists().not()&#xA;   implies&#xA;      component.code.coding.where( code != 'eyeCondition' and code != 'diopterIncrement' and code != 'wearschedule' and code != '98908-7' and code != 'ophthalmoscopyMethod' ).exists()" />
        <source value="http://fhir.essilorluxottica.com/fhir/StructureDefinition/el-observation-finalrefraction" />
      </constraint>
      <constraint>
        <key value="ou-cannotcontain-refraction" />
        <severity value="error" />
        <human value="OU can only contain VA, PD and notes." />
        <expression value="bodySite.coding.where( code = 'ou' ).exists()&#xA;   implies&#xA;      component.code.coding.where( code != 'eyeCondition' and code != 'diopterIncrement' and code != 'wearschedule' and code != '98908-7' and code != 'ophthalmoscopyMethod' and code.matches('VA.*').not() and code.matches('pupillaryDistance.*').not() ).exists().not()" />
        <source value="http://fhir.essilorluxottica.com/fhir/StructureDefinition/el-observation-finalrefraction" />
      </constraint>
    </element>
    <element id="Observation.meta.extension">
      <path value="Observation.meta.extension" />
      <min value="1" />
    </element>
    <element id="Observation.meta.extension:organization">
      <path value="Observation.meta.extension" />
      <sliceName value="organization" />
      <min value="1" />
      <max value="1" />
      <type>
        <code value="Extension" />
        <profile value="http://fhir.essilorluxottica.com/fhir/StructureDefinition/el-meta-organization-extension" />
      </type>
    </element>
    <element id="Observation.meta.tag">
      <path value="Observation.meta.tag" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-metatag-vs" />
      </binding>
    </element>
    <element id="Observation.identifier">
      <path value="Observation.identifier" />
      <slicing>
        <discriminator>
          <type value="value" />
          <path value="system" />
        </discriminator>
        <rules value="open" />
      </slicing>
    </element>
    <element id="Observation.identifier:refractionID">
      <path value="Observation.identifier" />
      <sliceName value="refractionID" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.identifier:refractionID.system">
      <path value="Observation.identifier.system" />
      <min value="1" />
      <patternUri value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-grouping-cs" />
    </element>
    <element id="Observation.identifier:refractionID.value">
      <path value="Observation.identifier.value" />
      <min value="1" />
    </element>
    <element id="Observation.identifier:externalSystemID">
      <path value="Observation.identifier" />
      <sliceName value="externalSystemID" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.identifier:externalSystemID.system">
      <path value="Observation.identifier.system" />
      <min value="1" />
      <patternUri value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-externalSystem-cs" />
    </element>
    <element id="Observation.identifier:externalSystemID.value">
      <path value="Observation.identifier.value" />
      <min value="1" />
    </element>
    <element id="Observation.status">
      <path value="Observation.status" />
      <patternCode value="final" />
    </element>
    <element id="Observation.category">
      <path value="Observation.category" />
      <patternCodeableConcept>
        <coding>
          <system value="http://terminology.hl7.org/CodeSystem/observation-category" />
          <code value="exam" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.code">
      <path value="Observation.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-sectioncode-cs" />
          <code value="finalRefraction" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.subject">
      <path value="Observation.subject" />
      <min value="1" />
      <type>
        <code value="Reference" />
        <targetProfile value="http://fhir.essilorluxottica.com/fhir/StructureDefinition/el-patient" />
      </type>
    </element>
    <element id="Observation.encounter">
      <path value="Observation.encounter" />
      <min value="1" />
    </element>
    <element id="Observation.note">
      <path value="Observation.note" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.bodySite">
      <path value="Observation.bodySite" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-eyelocation-vs" />
      </binding>
    </element>
    <element id="Observation.component">
      <path value="Observation.component" />
      <slicing>
        <discriminator>
          <type value="value" />
          <path value="code" />
        </discriminator>
        <description value="Slice based on the component.code value" />
        <rules value="open" />
      </slicing>
    </element>
    <element id="Observation.component:eyewearUseType">
      <path value="Observation.component" />
      <sliceName value="eyewearUseType" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:eyewearUseType.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="eyewearUseType" />
          <display value="Eyewear Use Type" />
        </coding>
      </patternCodeableConcept>
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:eyewearUseType.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="string" />
      </type>
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:eyeCondition">
      <path value="Observation.component" />
      <sliceName value="eyeCondition" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:eyeCondition.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="eyeCondition" />
          <display value="Eye Condition" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:eyeCondition.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-eyecondition-vs" />
      </binding>
    </element>
    <element id="Observation.component:diopterIncrement">
      <path value="Observation.component" />
      <sliceName value="diopterIncrement" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:diopterIncrement.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="diopterIncrement" />
          <display value="[diop] Measure Increment" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:diopterIncrement.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:diopterIncrement.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:roomBrightnessLevel">
      <path value="Observation.component" />
      <sliceName value="roomBrightnessLevel" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:roomBrightnessLevel.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://loinc.org" />
          <code value="98908-7" />
          <display value="Type of Room brightness level during testing" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:roomBrightnessLevel.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-brightnessLevelLoincCode-vs" />
      </binding>
    </element>
    <element id="Observation.component:powerOfSphere">
      <path value="Observation.component" />
      <sliceName value="powerOfSphere" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:powerOfSphere.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="powerOfSphere" />
          <display value="Power of sphere" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:powerOfSphere.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:powerOfSphere.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:powerOfCylinder">
      <path value="Observation.component" />
      <sliceName value="powerOfCylinder" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:powerOfCylinder.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="powerOfCylinder" />
          <display value="Power of cylinder" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:powerOfCylinder.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:powerOfCylinder.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:axisOfCylinder">
      <path value="Observation.component" />
      <sliceName value="axisOfCylinder" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:axisOfCylinder.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="axisOfCylinder" />
          <display value="Axis of cylinder" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:axisOfCylinder.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:axisOfCylinder.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:additionPower">
      <path value="Observation.component" />
      <sliceName value="additionPower" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:additionPower.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="additionPower" />
          <display value="Addition Power" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:additionPower.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:additionPower.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:horizontalPrismAmount">
      <path value="Observation.component" />
      <sliceName value="horizontalPrismAmount" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:horizontalPrismAmount.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="horizontalPrismAmount" />
          <display value="Horizontal Prism Amount of Adjustment" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:horizontalPrismAmount.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:horizontalPrismAmount.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:horizontalPrismBase">
      <path value="Observation.component" />
      <sliceName value="horizontalPrismBase" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:horizontalPrismBase.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="horizontalPrismBase" />
          <display value="Horizontal Prism Base" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:horizontalPrismBase.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://hl7.org/fhir/ValueSet/vision-base-codes" />
      </binding>
    </element>
    <element id="Observation.component:verticalPrismAmount">
      <path value="Observation.component" />
      <sliceName value="verticalPrismAmount" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:verticalPrismAmount.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="verticalPrismAmount" />
          <display value="Vertical Prism Amount of Adjustment" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:verticalPrismAmount.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:verticalPrismAmount.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="[diop]" />
    </element>
    <element id="Observation.component:verticalPrismBase">
      <path value="Observation.component" />
      <sliceName value="verticalPrismBase" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:verticalPrismBase.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="verticalPrismBase" />
          <display value="Vertical Prism Base" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:verticalPrismBase.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://hl7.org/fhir/ValueSet/vision-base-codes" />
      </binding>
    </element>
    <element id="Observation.component:vertexDistance">
      <path value="Observation.component" />
      <sliceName value="vertexDistance" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:vertexDistance.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="vertexDistance" />
          <display value="Vertex Distance" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:vertexDistance.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:vertexDistance.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="mm" />
    </element>
    <element id="Observation.component:pupillaryDistanceDistance">
      <path value="Observation.component" />
      <sliceName value="pupillaryDistanceDistance" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:pupillaryDistanceDistance.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="pupillaryDistanceDistance" />
          <display value="Pupillary Distance distance" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:pupillaryDistanceDistance.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:pupillaryDistanceDistance.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="mm" />
    </element>
    <element id="Observation.component:pupillaryDistanceNear">
      <path value="Observation.component" />
      <sliceName value="pupillaryDistanceNear" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:pupillaryDistanceNear.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="pupillaryDistanceNear" />
          <display value="Pupillary distance Distance" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:pupillaryDistanceNear.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:pupillaryDistanceNear.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="mm" />
    </element>
    <element id="Observation.component:VAdistanceDecimal">
      <path value="Observation.component" />
      <sliceName value="VAdistanceDecimal" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAdistanceDecimal.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAdistanceDecimal" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAdistanceDecimal.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:VAdistanceDecimal.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="decimal" />
    </element>
    <element id="Observation.component:VAdistanceRatio">
      <path value="Observation.component" />
      <sliceName value="VAdistanceRatio" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAdistanceRatio.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAdistanceRatio" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAdistanceRatio.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Ratio" />
      </type>
    </element>
    <element id="Observation.component:VAdistanceRatio.value[x].numerator.unit">
      <path value="Observation.component.value[x].numerator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAdistanceRatio.value[x].denominator.unit">
      <path value="Observation.component.value[x].denominator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAdistancePlusMinusLetters">
      <path value="Observation.component" />
      <sliceName value="VAdistancePlusMinusLetters" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAdistancePlusMinusLetters.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAdistancePlusMinusLetters" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAdistancePlusMinusLetters.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="integer" />
      </type>
    </element>
    <element id="Observation.component:VAdistanceCode">
      <path value="Observation.component" />
      <sliceName value="VAdistanceCode" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAdistanceCode.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAdistanceCode" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAdistanceCode.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityCode-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAnearDecimal">
      <path value="Observation.component" />
      <sliceName value="VAnearDecimal" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAnearDecimal.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAnearDecimal" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAnearDecimal.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:VAnearDecimal.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="decimal" />
    </element>
    <element id="Observation.component:VAnearRatio">
      <path value="Observation.component" />
      <sliceName value="VAnearRatio" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAnearRatio.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAnearRatio" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAnearRatio.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Ratio" />
      </type>
    </element>
    <element id="Observation.component:VAnearRatio.value[x].numerator.unit">
      <path value="Observation.component.value[x].numerator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAnearRatio.value[x].denominator.unit">
      <path value="Observation.component.value[x].denominator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAnearPlusMinusLetters">
      <path value="Observation.component" />
      <sliceName value="VAnearPlusMinusLetters" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAnearPlusMinusLetters.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAnearPlusMinusLetters" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAnearPlusMinusLetters.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="integer" />
      </type>
    </element>
    <element id="Observation.component:VAnearCode">
      <path value="Observation.component" />
      <sliceName value="VAnearCode" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAnearCode.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAnearCode" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAnearCode.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityCode-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAglareDecimal">
      <path value="Observation.component" />
      <sliceName value="VAglareDecimal" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAglareDecimal.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAglareDecimal" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAglareDecimal.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:VAglareDecimal.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="decimal" />
    </element>
    <element id="Observation.component:VAglareRatio">
      <path value="Observation.component" />
      <sliceName value="VAglareRatio" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAglareRatio.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAglareRatio" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAglareRatio.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Ratio" />
      </type>
    </element>
    <element id="Observation.component:VAglareRatio.value[x].numerator.unit">
      <path value="Observation.component.value[x].numerator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAglareRatio.value[x].denominator.unit">
      <path value="Observation.component.value[x].denominator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VAglarePlusMinusLetters">
      <path value="Observation.component" />
      <sliceName value="VAglarePlusMinusLetters" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAglarePlusMinusLetters.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAglarePlusMinusLetters" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAglarePlusMinusLetters.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="integer" />
      </type>
    </element>
    <element id="Observation.component:VAglareCode">
      <path value="Observation.component" />
      <sliceName value="VAglareCode" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VAglareCode.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VAglareCode" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VAglareCode.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityCode-vs" />
      </binding>
    </element>
    <element id="Observation.component:VApinholeDecimal">
      <path value="Observation.component" />
      <sliceName value="VApinholeDecimal" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VApinholeDecimal.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VApinholeDecimal" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VApinholeDecimal.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:VApinholeDecimal.value[x].unit">
      <path value="Observation.component.value[x].unit" />
      <patternString value="decimal" />
    </element>
    <element id="Observation.component:VApinholeRatio">
      <path value="Observation.component" />
      <sliceName value="VApinholeRatio" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VApinholeRatio.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VApinholeRatio" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VApinholeRatio.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Ratio" />
      </type>
    </element>
    <element id="Observation.component:VApinholeRatio.value[x].numerator.unit">
      <path value="Observation.component.value[x].numerator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VApinholeRatio.value[x].denominator.unit">
      <path value="Observation.component.value[x].denominator.unit" />
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityRatioUnit-vs" />
      </binding>
    </element>
    <element id="Observation.component:VApinholePlusMinusLetters">
      <path value="Observation.component" />
      <sliceName value="VApinholePlusMinusLetters" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VApinholePlusMinusLetters.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VApinholePlusMinusLetters" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VApinholePlusMinusLetters.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="integer" />
      </type>
    </element>
    <element id="Observation.component:VApinholeCode">
      <path value="Observation.component" />
      <sliceName value="VApinholeCode" />
      <min value="0" />
      <max value="1" />
      <mustSupport value="true" />
    </element>
    <element id="Observation.component:VApinholeCode.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://fhir.essilorluxottica.com/fhir/CodeSystem/el-observation-componentcode-cs" />
          <code value="VApinholeCode" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:VApinholeCode.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="CodeableConcept" />
      </type>
      <binding>
        <strength value="required" />
        <valueSet value="http://fhir.essilorluxottica.com/fhir/ValueSet/el-observation-visualAcuityCode-vs" />
      </binding>
    </element>
  </differential>
</StructureDefinition>