<ValueSet xmlns="http://hl7.org/fhir">
  <id value="spark775" />
  <meta>
    <versionId value="spark775" />
    <lastUpdated value="2015-10-02T12:29:56.596+00:00" />
    <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition" />
  </meta>
  <text>
    <status value="additional" />
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p>Specimen Role</p>
      <table class="grid">
        <tr>
          <td>
            <b>Code</b>
          </td>
          <td>
            <b>Description</b>
          </td>
          <td>
            <b>Comment</b>
          </td>
          <td>
            <b>Version</b>
          </td>
        </tr>
        <tr>
          <td>B
                  <a name="B"></a></td>
          <td>Blind Sample</td>
          <td />
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>C
                  <a name="C"></a></td>
          <td>Calibrator, used for initial setting of calibration</td>
          <td />
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>E
                  <a name="E"></a></td>
          <td>Electronic QC, used with manufactured reference providing signals that simulate QC results</td>
          <td />
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>F
                  <a name="F"></a></td>
          <td>Specimen used for testing proficiency of the organization performing the testing (Filler)</td>
          <td />
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>G
                  <a name="G"></a></td>
          <td>Group (where a specimen consists of multiple individual elements that are not individually identified)</td>
          <td />
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>L
                  <a name="L"></a></td>
          <td>Pool (aliquots of individual specimens combined to form a single specimen representing all of the components.)</td>
          <td />
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>O
                  <a name="O"></a></td>
          <td>Specimen used for testing Operator Proficiency</td>
          <td />
          <td>added v2.5</td>
        </tr>
        <tr>
          <td>P
                  <a name="P"></a></td>
          <td>Patient (default if blank component value)</td>
          <td />
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>Q
                  <a name="Q"></a></td>
          <td>Control specimen</td>
          <td />
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>R
                  <a name="R"></a></td>
          <td>Replicate (of patient sample as a control)</td>
          <td />
          <td>added v2.4</td>
        </tr>
        <tr>
          <td>V
                  <a name="V"></a></td>
          <td>Verifying Calibrator, used for periodic calibration checks</td>
          <td />
          <td>added v2.5</td>
        </tr>
      </table>
    </div>
  </text>
  <url value="http://hl7.org/fhir/ValueSet/v2-0369" />
  <version value="2.8.2" />
  <name value="v2 Specimen Role" />
  <status value="active" />
  <experimental value="true" />
  <publisher value="HL7, Inc" />
  <contact>
    <telecom>
      <system value="other" />
      <value value="http://hl7.org" />
    </telecom>
  </contact>
  <description value="FHIR Value set/code system definition for HL7 v2 table 0369 ( Specimen Role)" />
  <codeSystem>
    <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid">
      <valueUri value="urn:oid:2.16.840.1.133883.18.227" />
    </extension>
    <system value="http://hl7.org/fhir/v2/0369" />
    <caseSensitive value="false" />
    <concept>
      <code value="B" />
      <display value="Blind Sample" />
    </concept>
    <concept>
      <code value="C" />
      <display value="Calibrator, used for initial setting of calibration" />
    </concept>
    <concept>
      <code value="E" />
      <display value="Electronic QC, used with manufactured reference providing signals that simulate QC results" />
    </concept>
    <concept>
      <code value="F" />
      <display value="Specimen used for testing proficiency of the organization performing the testing (Filler)" />
    </concept>
    <concept>
      <code value="G" />
      <display value="Group (where a specimen consists of multiple individual elements that are not individually identified)" />
    </concept>
    <concept>
      <code value="L" />
      <display value="Pool (aliquots of individual specimens combined to form a single specimen representing all of the components.)" />
    </concept>
    <concept>
      <code value="O" />
      <display value="Specimen used for testing Operator Proficiency" />
    </concept>
    <concept>
      <code value="P" />
      <display value="Patient (default if blank component value)" />
    </concept>
    <concept>
      <code value="Q" />
      <display value="Control specimen" />
    </concept>
    <concept>
      <code value="R" />
      <display value="Replicate (of patient sample as a control)" />
    </concept>
    <concept>
      <code value="V" />
      <display value="Verifying Calibrator, used for periodic calibration checks" />
    </concept>
  </codeSystem>
</ValueSet>