  "resourceType": "StructureDefinition",
  "id": "logicalmodel-Tympanogramtestresult-226hz-R4",
  "url": "http://linkehr.com/fhir/logicalmodel-tympanogramtestresult-226hz-R4",
  "identifier": [
    {
      "system": "openEHR-CKM",
      "value": "openEHR-EHR-OBSERVATION.tympanogram_226hz.v0"
    }
  ],
  "version": "0",
  "name": "Tympanogramtestresult-226hz",
  "title": "Tympanogram test result - 226Hz",
  "status": "draft",
  "date": "2024-06-18",
  "publisher": "openEHR",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.veratech.es"
        }
      ]
    }
  ],
  "description": "Record of measurements of movement at the tympanic membrane in response to a 226Hz probe tone and changes in air pressure in the ear canal, and their clinical interpretation as an indication of middle ear function.",
  "purpose": "To record measurements based on a 226 Hz probe tone, of the admittance or impedance of the middle ear system as a function of changing the external ear canal pressure.\r\n\r\nTo infer middle ear function from objective measurements based on a fixed 226Hz probe tone, taken at the tympanic membrane of the mobility of the tympanic membrane, in reponse to varying air pressure in the ear canal.",
  "fhirVersion": "4.0.0",
  "mapping": [
    {
      "identity": "openEHR",
      "uri": "http://openehr.org",
      "name": "openEHR Mapping"
    },
    {
      "identity": "openEHR-natural",
      "uri": "http://openehr.org",
      "name": "openEHR natural path"
    }
  ],
  "kind": "logical",
  "abstract": false,
  "type": "StructureDefinition",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Element",
  "snapshot": {
    "element": [
      {
        "id": "Tympanogram_test_result___226Hz",
        "path": "Tympanogram_test_result___226Hz",
        "short": "Tympanogram test result - 226Hz",
        "definition": "Record of measurements of movement at the tympanic membrane in response to a 226Hz probe tone and changes in air pressure in the ear canal, and their clinical interpretation as an indication of middle ear function.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol",
        "path": "Tympanogram_test_result___226Hz.protocol",
        "short": "Tree",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Direction_of_pressure_change",
        "path": "Tympanogram_test_result___226Hz.protocol.Direction_of_pressure_change",
        "short": "Direction of pressure change",
        "definition": "The dirction of change of pressure administered via the ear canal.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Direction_of_pressure_change",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Direction_of_pressure_change.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Direction_of_pressure_change.value",
        "short": "Direction of pressure change",
        "definition": "The dirction of change of pressure administered via the ear canal.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Direction_of_pressure_change.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Rate_of_pressure_change",
        "path": "Tympanogram_test_result___226Hz.protocol.Rate_of_pressure_change",
        "short": "Rate of pressure change",
        "definition": "The rate of change of pressure used in tympanometry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Rate_of_pressure_change",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Rate_of_pressure_change.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Rate_of_pressure_change.value",
        "short": "Rate of pressure change",
        "definition": "The rate of change of pressure used in tympanometry.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Rate_of_pressure_change.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Admittance_measurement",
        "path": "Tympanogram_test_result___226Hz.protocol.Admittance_measurement",
        "short": "Admittance measurement",
        "definition": "Method of acoustic admittance measurement used in the test.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Admittance_measurement",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Admittance_measurement.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Admittance_measurement.value",
        "short": "Admittance measurement",
        "definition": "Method of acoustic admittance measurement used in the test.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Admittance_measurement.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pressure_range",
        "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range",
        "short": "Pressure range",
        "definition": "The range of air pressure used to determine the tympanogram.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Start_pressure",
        "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Start_pressure",
        "short": "Start pressure",
        "definition": "The pressure value in daPa at which the pressure sweep for tympanometry begins. It is a positive pressure if the direction of pressure change is descending and a negative pressure if the direction of pressure change is ascending.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Start_pressure",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Start_pressure.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Start_pressure.value",
        "short": "Start pressure",
        "definition": "The pressure value in daPa at which the pressure sweep for tympanometry begins. It is a positive pressure if the direction of pressure change is descending and a negative pressure if the direction of pressure change is ascending.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Start_pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Stop_pressure",
        "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Stop_pressure",
        "short": "Stop pressure",
        "definition": "The pressure value in daPa at which the pressure sweep for tympanometry ends. It is a negative pressure if the direction of pressure change is descending and a positive pressure if the direction of pressure change is ascending.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Stop_pressure",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Stop_pressure.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Stop_pressure.value",
        "short": "Stop pressure",
        "definition": "The pressure value in daPa at which the pressure sweep for tympanometry ends. It is a negative pressure if the direction of pressure change is descending and a positive pressure if the direction of pressure change is ascending.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pressure_range.Stop_pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Tympanometer",
        "path": "Tympanogram_test_result___226Hz.protocol.Tympanometer",
        "short": "Tympanometer",
        "definition": "Details of tympanometer used to conduct the test.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Tympanometer",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pre_test_calibration_cavity_size",
        "path": "Tympanogram_test_result___226Hz.protocol.Pre_test_calibration_cavity_size",
        "short": "Pre-test calibration cavity size",
        "definition": "A cavity with a known volume used to check the calibration of the tympanometer.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pre_test_calibration_cavity_size",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Pre_test_calibration_cavity_size.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Pre_test_calibration_cavity_size.value",
        "short": "Pre-test calibration cavity size",
        "definition": "A cavity with a known volume used to check the calibration of the tympanometer.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Pre_test_calibration_cavity_size.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Comment",
        "path": "Tympanogram_test_result___226Hz.protocol.Comment",
        "short": "Comment",
        "definition": "Additional narrative about the protocol for the tympanogram not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Comment",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.protocol.Comment.value",
        "path": "Tympanogram_test_result___226Hz.protocol.Comment.value",
        "short": "Comment",
        "definition": "Additional narrative about the protocol for the tympanogram not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.protocol.Comment.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series",
        "path": "Tympanogram_test_result___226Hz.Event_Series",
        "short": "Event Series",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event",
        "short": "Any event",
        "definition": "Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data",
        "short": "Tree",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details",
        "short": "Result details",
        "definition": "The tympanogram test result measurements and interpretations, recorded per ear.",
        "min": 0,
        "max": "2",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details",
          "min": 0,
          "max": "2"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Test_ear",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Test_ear",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Test_ear",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Test_ear.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Test_ear.value",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Test_ear.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details",
        "short": "Measurement details",
        "definition": "Measurements of the tympanogram to infer middle ear function.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "short": "Pressure vs compliance measurement",
        "definition": "The Pressure/Compliance measurement pair, captured from a tympanometer and used to define a continuous tympanogram curve.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Peak_pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Peak_pressure",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Peak_pressure",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Peak_pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Peak_pressure.value",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Peak_pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Ear_canal_volume",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Ear_canal_volume",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Ear_canal_volume",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Ear_canal_volume.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_width",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_width",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_width",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_width.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_width.value",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_width.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.No_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.No_test_result",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.No_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.No_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.No_test_result.value",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.No_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "boolean"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Reason_for_no_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Reason_for_no_test_result",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Reason_for_no_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Reason_for_no_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Reason_for_no_test_result.value",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Reason_for_no_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type.value",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_B_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_B_subtype",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_B_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_B_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_B_subtype.value",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_B_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_C_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_C_subtype",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_C_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_C_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_C_subtype.value",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Tympanogram_type_C_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Clinical_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Clinical_interpretation",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Clinical_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Clinical_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Clinical_interpretation.value",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Result_details.Clinical_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Overall_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Overall_interpretation",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Overall_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Overall_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Overall_interpretation.value",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Overall_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Test_result_image",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Test_result_image",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Test_result_image",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Test_result_image.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Test_result_image.value",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Test_result_image.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Attachment"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Comment",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Comment",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Comment",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Comment.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Comment.value",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Any_event.data.Comment.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline",
        "short": "Baseline",
        "definition": "Measurement collection recorded as the basis for comparison with following measurement collections that may include other variables of time or patient state.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data",
        "definition": "ITEM_TREE",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details",
        "short": "Result details",
        "definition": "The tympanogram test result measurements and interpretations, recorded per ear.",
        "min": 0,
        "max": "2",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details",
          "min": 0,
          "max": "2"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Test_ear",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Test_ear",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Test_ear",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Test_ear.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Test_ear.value",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Test_ear.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details",
        "short": "Measurement details",
        "definition": "Measurements of the tympanogram to infer middle ear function.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "short": "Pressure vs compliance measurement",
        "definition": "The Pressure/Compliance measurement pair, captured from a tympanometer and used to define a continuous tympanogram curve.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Peak_pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Peak_pressure",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Peak_pressure",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Peak_pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Peak_pressure.value",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Peak_pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Ear_canal_volume",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Ear_canal_volume",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Ear_canal_volume",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Ear_canal_volume.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_width",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_width",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_width",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_width.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_width.value",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_width.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.No_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.No_test_result",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.No_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.No_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.No_test_result.value",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.No_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "boolean"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Reason_for_no_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Reason_for_no_test_result",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Reason_for_no_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Reason_for_no_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Reason_for_no_test_result.value",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Reason_for_no_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type.value",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_B_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_B_subtype",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_B_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_B_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_B_subtype.value",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_B_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_C_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_C_subtype",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_C_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_C_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_C_subtype.value",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Tympanogram_type_C_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Clinical_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Clinical_interpretation",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Clinical_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Clinical_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Clinical_interpretation.value",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Result_details.Clinical_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Overall_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Overall_interpretation",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Overall_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Overall_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Overall_interpretation.value",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Overall_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Test_result_image",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Test_result_image",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Test_result_image",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Test_result_image.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Test_result_image.value",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Test_result_image.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Attachment"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Comment",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Comment",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Comment",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Comment.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Comment.value",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Baseline.data.Comment.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva",
        "short": "Post-Valsalva",
        "definition": "Measurements are recorded after the patient has performed a valsalva manoeuvre.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data",
        "definition": "ITEM_TREE",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details",
        "short": "Result details",
        "definition": "The tympanogram test result measurements and interpretations, recorded per ear.",
        "min": 0,
        "max": "2",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details",
          "min": 0,
          "max": "2"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Test_ear",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Test_ear",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Test_ear",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Test_ear.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Test_ear.value",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Test_ear.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details",
        "short": "Measurement details",
        "definition": "Measurements of the tympanogram to infer middle ear function.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "short": "Pressure vs compliance measurement",
        "definition": "The Pressure/Compliance measurement pair, captured from a tympanometer and used to define a continuous tympanogram curve.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Peak_pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Peak_pressure",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Peak_pressure",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Peak_pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Peak_pressure.value",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Peak_pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Ear_canal_volume",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Ear_canal_volume",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Ear_canal_volume",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Ear_canal_volume.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_width",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_width",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_width",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_width.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_width.value",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_width.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.No_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.No_test_result",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.No_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.No_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.No_test_result.value",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.No_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "boolean"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Reason_for_no_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Reason_for_no_test_result",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Reason_for_no_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Reason_for_no_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Reason_for_no_test_result.value",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Reason_for_no_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type.value",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_B_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_B_subtype",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_B_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_B_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_B_subtype.value",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_B_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_C_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_C_subtype",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_C_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_C_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_C_subtype.value",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Tympanogram_type_C_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Clinical_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Clinical_interpretation",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Clinical_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Clinical_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Clinical_interpretation.value",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Result_details.Clinical_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Overall_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Overall_interpretation",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Overall_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Overall_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Overall_interpretation.value",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Overall_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Test_result_image",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Test_result_image",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Test_result_image",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Test_result_image.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Test_result_image.value",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Test_result_image.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Attachment"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Comment",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Comment",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Comment",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Comment.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Comment.value",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Valsalva.data.Comment.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee",
        "short": "Post-Toynbee",
        "definition": "Measurements are recorded after the patient has performed a toynbee manoeuvre.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data",
        "definition": "ITEM_TREE",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details",
        "short": "Result details",
        "definition": "The tympanogram test result measurements and interpretations, recorded per ear.",
        "min": 0,
        "max": "2",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details",
          "min": 0,
          "max": "2"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Test_ear",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Test_ear",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Test_ear",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Test_ear.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Test_ear.value",
        "short": "Test ear",
        "definition": "Identification of the ear being tested.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Test_ear.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details",
        "short": "Measurement details",
        "definition": "Measurements of the tympanogram to infer middle ear function.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
        "short": "Pressure vs compliance measurement",
        "definition": "The Pressure/Compliance measurement pair, captured from a tympanometer and used to define a continuous tympanogram curve.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure",
          "min": 1,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
        "short": "Pressure",
        "definition": "The pressure measured in the ear canal.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
        "short": "Compliance (volume)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in cc3 or ml.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
        "short": "Compliance (conductance)",
        "definition": "The amount of acoustic energy absorbed by the middle ear system at a specified pressure, measured in mmHo.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Pressure_vs_compliance_measurement.Compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Peak_pressure",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Peak_pressure",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Peak_pressure",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Peak_pressure.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Peak_pressure.value",
        "short": "Peak pressure",
        "definition": "Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak of the tympanogram occurs.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Peak_pressure.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(volume)",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(volume)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(volume).value",
        "short": "Static compliance (volume)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(volume).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(conductance)",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(conductance)",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
        "short": "Static compliance (conductance)",
        "definition": "Static compliance (SC) is the greatest amount of acoustic energy absorbed by the middle ear system (the vertical peak of the tympanogram curve).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Static_compliance_(conductance).value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Ear_canal_volume",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Ear_canal_volume",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Ear_canal_volume",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Ear_canal_volume.value",
        "short": "Ear canal volume",
        "definition": "An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler & Shanks, 2002, p. 180).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Ear_canal_volume.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_width",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_width",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_width",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_width.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_width.value",
        "short": "Tympanometric width",
        "definition": "The pressure interval corresponding to a 50% reduction in the peak static admittance.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_width.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient.value_DvQuantity",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
        "short": "Tympanometric gradient",
        "definition": "The steepness of the slope of the tympanogram near the peak.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Measurement_details.Tympanometric_gradient.value_DV_PROPORTION",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.No_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.No_test_result",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.No_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.No_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.No_test_result.value",
        "short": "No test result",
        "definition": "No test result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.No_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "boolean"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Reason_for_no_test_result",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Reason_for_no_test_result",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Reason_for_no_test_result",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Reason_for_no_test_result.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Reason_for_no_test_result.value",
        "short": "Reason for no test result",
        "definition": "Reason why no result is available for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Reason_for_no_test_result.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type.value",
        "short": "Tympanogram type",
        "definition": "Description of the the shape of the tympanogram curve, based on the Jerger categories.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_B_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_B_subtype",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_B_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_B_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_B_subtype.value",
        "short": "Tympanogram type B subtype",
        "definition": "Subclassification of the tympanograms with a flat curve.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_B_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_C_subtype",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_C_subtype",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_C_subtype",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_C_subtype.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_C_subtype.value",
        "short": "Tympanogram type C subtype",
        "definition": "Subclassification of the tympanograms with negative peak pressure.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Tympanogram_type_C_subtype.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Clinical_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Clinical_interpretation",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Clinical_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Clinical_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Clinical_interpretation.value",
        "short": "Clinical interpretation",
        "definition": "Clinical interpretation of all measurements for the test ear.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Result_details.Clinical_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Overall_interpretation",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Overall_interpretation",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Overall_interpretation",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Overall_interpretation.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Overall_interpretation.value",
        "short": "Overall interpretation",
        "definition": "Overall clinical interpretation of the measurements and related findings using an tympanometer.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Overall_interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Test_result_image",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Test_result_image",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Test_result_image",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Test_result_image.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Test_result_image.value",
        "short": "Test result image",
        "definition": "Digital representation of the entire result.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Test_result_image.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Attachment"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Comment",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Comment",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Comment",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Comment.value",
        "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Comment.value",
        "short": "Comment",
        "definition": "Additional narrative about the test results and intepretation not captured in other fields.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Tympanogram_test_result___226Hz.Event_Series.Post_Toynbee.data.Comment.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      }
    ]
  }
}