  "resourceType": "StructureDefinition",
  "id": "logicalmodel-Pulseoximetry-R4",
  "url": "http://linkehr.com/fhir/logicalmodel-pulseoximetry-R4",
  "identifier": [
    {
      "system": "openEHR-CKM",
      "value": "openEHR-EHR-OBSERVATION.pulse_oximetry.v1"
    }
  ],
  "version": "0",
  "name": "Pulseoximetry",
  "title": "Pulse oximetry",
  "status": "draft",
  "date": "2024-06-18",
  "publisher": "openEHR",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.veratech.es"
        }
      ]
    }
  ],
  "description": "Blood oxygen and related measurements, measured by pulse oximetry or pulse CO-oximetry.",
  "purpose": "To record blood oxygen and related measurements, measured by pulse oximetry or pulse CO-oximetry.",
  "fhirVersion": "4.0.0",
  "mapping": [
    {
      "identity": "openEHR",
      "uri": "http://openehr.org",
      "name": "openEHR Mapping"
    },
    {
      "identity": "openEHR-natural",
      "uri": "http://openehr.org",
      "name": "openEHR natural path"
    }
  ],
  "kind": "logical",
  "abstract": false,
  "type": "StructureDefinition",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Element",
  "snapshot": {
    "element": [
      {
        "id": "Pulse_oximetry",
        "path": "Pulse_oximetry",
        "short": "Pulse oximetry",
        "definition": "Blood oxygen and related measurements, measured by pulse oximetry or pulse CO-oximetry.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.List",
        "path": "Pulse_oximetry.List",
        "short": "List",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.List",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.List.Sensor_site",
        "path": "Pulse_oximetry.List.Sensor_site",
        "short": "Sensor site",
        "definition": "The site of the measurement sensor.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.List.Sensor_site",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.List.Sensor_site.value",
        "path": "Pulse_oximetry.List.Sensor_site.value",
        "short": "Sensor site",
        "definition": "The site of the measurement sensor.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.List.Sensor_site.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.List.Pre_post_ductal",
        "path": "Pulse_oximetry.List.Pre_post_ductal",
        "short": "Pre/post-ductal",
        "definition": "Sensor site relative to the ductus arteriosus in neonates, to determine whether the blood supply to limb of the sensor site is pre- or post-ductal in cases of patent ductus arteriosus.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.List.Pre_post_ductal",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.List.Pre_post_ductal.value",
        "path": "Pulse_oximetry.List.Pre_post_ductal.value",
        "short": "Pre/post-ductal",
        "definition": "Sensor site relative to the ductus arteriosus in neonates, to determine whether the blood supply to limb of the sensor site is pre- or post-ductal in cases of patent ductus arteriosus.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.List.Pre_post_ductal.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.List.Oximetry_device",
        "path": "Pulse_oximetry.List.Oximetry_device",
        "short": "Oximetry device",
        "definition": "Details of the non-invasive oximetry device used.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.List.Oximetry_device",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.List.Extension",
        "path": "Pulse_oximetry.List.Extension",
        "short": "Extension",
        "definition": "Additional information required to capture local context or to align with other reference models/formalisms.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Pulse_oximetry.List.Extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series",
        "path": "Pulse_oximetry.Event_Series",
        "short": "Event Series",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event",
        "path": "Pulse_oximetry.Event_Series.Any_event",
        "short": "Any event",
        "definition": "Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data",
        "path": "Pulse_oximetry.Event_Series.Any_event.data",
        "short": "Tree",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpO₂",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpO₂",
        "short": "SpO₂",
        "definition": "The saturation of oxygen in the peripheral blood, measured via pulse oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpO₂",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpO₂.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpO₂.value",
        "short": "SpO₂",
        "definition": "The saturation of oxygen in the peripheral blood, measured via pulse oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpO₂.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpOC",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpOC",
        "short": "SpOC",
        "definition": "The oxygen content of the peripheral blood, calculated based on pulse oximetry and pulse CO-oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpOC",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpOC.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpOC.value",
        "short": "SpOC",
        "definition": "The oxygen content of the peripheral blood, calculated based on pulse oximetry and pulse CO-oximetry.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpOC.value",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpCO",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpCO",
        "short": "SpCO",
        "definition": "The saturation of carboxyhaemoglobin in the peripheral blood, measured via pulse CO-oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpCO",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpCO.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpCO.value",
        "short": "SpCO",
        "definition": "The saturation of carboxyhaemoglobin in the peripheral blood, measured via pulse CO-oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpCO.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpMet",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpMet",
        "short": "SpMet",
        "definition": "The saturation of methaemoglobin in the peripheral blood, measured via pulse CO-oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpMet",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.SpMet.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.SpMet.value",
        "short": "SpMet",
        "definition": "The saturation of methaemoglobin in the peripheral blood, measured via pulse CO-oximetry.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.SpMet.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Ratio"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.Waveform",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.Waveform",
        "short": "Waveform",
        "definition": "A waveform reading associated with the oximetry measurement.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.Waveform",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.Multimedia_image",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.Multimedia_image",
        "short": "Multimedia image",
        "definition": "Details of a series of oximetry readings, other than waveforms, expressed as a multimedia image or series of images. Waveforms should be recorded using the Waveform slot and associated cluster archetype.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.Multimedia_image",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.Interpretation",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.Interpretation",
        "short": "Interpretation",
        "definition": "Single word, phrase or brief description which represents the clinical meaning and significance of the measurements.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.Interpretation",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.Interpretation.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.Interpretation.value",
        "short": "Interpretation",
        "definition": "Single word, phrase or brief description which represents the clinical meaning and significance of the measurements.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.Interpretation.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.Comment",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.Comment",
        "short": "Comment",
        "definition": "A text comment about the pulse oximetry result.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.Comment",
          "min": 0,
          "max": "1"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.data.Comment.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.data.Comment.value",
        "short": "Comment",
        "definition": "A text comment about the pulse oximetry result.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.data.Comment.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.state",
        "path": "Pulse_oximetry.Event_Series.Any_event.state",
        "short": "Tree",
        "definition": "@ internal @",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.state",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.state.Exertion",
        "path": "Pulse_oximetry.Event_Series.Any_event.state.Exertion",
        "short": "Exertion",
        "definition": "Details about physical activity undertaken at the time of measurement.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.state.Exertion",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.state.Inspired_oxygen",
        "path": "Pulse_oximetry.Event_Series.Any_event.state.Inspired_oxygen",
        "short": "Inspired oxygen",
        "definition": "Details of the amount of oxygen available to the subject at the time of observation.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.state.Inspired_oxygen",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.state.Confounding_factors",
        "path": "Pulse_oximetry.Event_Series.Any_event.state.Confounding_factors",
        "short": "Confounding factors",
        "definition": "Comment on and record other incidental factors that may be affect interpretation of the observation.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.state.Confounding_factors",
          "min": 0,
          "max": "*"
        }
      },
      {
        "id": "Pulse_oximetry.Event_Series.Any_event.state.Confounding_factors.value",
        "path": "Pulse_oximetry.Event_Series.Any_event.state.Confounding_factors.value",
        "short": "Confounding factors",
        "definition": "Comment on and record other incidental factors that may be affect interpretation of the observation.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Pulse_oximetry.Event_Series.Any_event.state.Confounding_factors.value",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": false,
        "isModifier": false,
        "isSummary": true
      }
    ]
  }
}