  "resourceType": "StructureDefinition",
  "id": "HdBe-Respiration",
  "language": "en-US",
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/resource-effectivePeriod",
      "valuePeriod": {
        "start": "2020-08-31T22:00:00+00:00"
      }
    }
  ],
  "url": "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-Respiration",
  "name": "HdBeRespiration",
  "_name": {
    "extension": [
      {
        "extension": [
          {
            "url": "lang",
            "valueCode": "nl-NL"
          },
          {
            "url": "content",
            "valueMarkdown": "HdBeAdemhaling"
          }
        ],
        "url": "http://hl7.org/fhir/StructureDefinition/translation"
      }
    ]
  },
  "title": "HdBe Respiration",
  "status": "draft",
  "date": "2022-07-07T15:04:03.2592055+00:00",
  "publisher": "Healthdata.be (Sciensano)",
  "contact": [
    {
      "name": "Service portal – healthdata.be",
      "telecom": [
        {
          "system": "url",
          "value": "https://sciensano.service-now.com/sp",
          "use": "work"
        }
      ]
    }
  ],
  "description": "During breathing or respiration, air flows to and from the lungs, where gas exchange occurs, absorbing oxygen from the air into the blood and exhaling carbon dioxide into the air. Observations of spontaneous breathing, usually registered as part of the observation of vital functions. \r\n#### Purpose\r\nObserving a person’s spontaneous breathing, including recording breathing frequency, depth and rhythm, is done to gain an indication of the health condition of the patient’s pulmonary system.",
  "_description": {
    "extension": [
      {
        "extension": [
          {
            "url": "lang",
            "valueCode": "nl-NL"
          },
          {
            "url": "content",
            "valueMarkdown": "Bij de ademhaling of respiratie stroomt er lucht naar en van de longen, waar de gasuitwisseling plaatsvindt, waarbij zuurstof vanuit de lucht wordt opgenomen in het bloed en koolstofdioxide wordt afgegeven aan de lucht. Observaties van de spontane ademhaling zoals deze meestal geregistreerd worden als onderdeel van de observatie van de vitale functies.\r\n#### Purpose\r\nHet observeren van de spontane ademhaling van een persoon, inclusief het vastleggen van de ademhalingsfrequentie, diepte en het ritme, wordt gedaan om een indruk te krijgen van de gezondheidstoestand van het pulmonaire systeem van de patiënt.\r\n\r\n\r\n**References**\r\n1. Parelsnoer DCM Ademhalingsfrequentie v0.4 [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/nl.parelsnoer.Ademhalingsfrequentie.v0.4.pdf [Geraadpleegd: 23 februari 2015].\r\n\r\n2. openEHR-EHR-OBSERVATION.respiration.v1 [Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 23 februari 2015]."
          }
        ],
        "url": "http://hl7.org/fhir/StructureDefinition/translation"
      }
    ]
  },
  "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "fhirVersion": "4.0.1",
  "kind": "logical",
  "abstract": true,
  "type": "https://fhir.healthdata.be/StructureDefinition/LogicalModel/Respiration",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Element",
  "derivation": "specialization",
  "snapshot": {
    "element": [
      {
        "id": "Respiration",
        "path": "Respiration",
        "short": "Respiration",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Ademhaling"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Root concept of the Breathing information model. This root concept contains all data elements of the Breathing information model.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Rootconcept van de bouwsteen Ademhaling. Dit rootconcept bevat alle gegevenselementen van de bouwsteen Ademhaling."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "*",
        "base": {
          "path": "Respiration",
          "min": 0,
          "max": "*"
        },
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.id",
        "path": "Respiration.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "xml:id (or equivalent in JSON)",
        "definition": "unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.extension",
        "path": "Respiration.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional Content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.BreathingFrequency",
        "path": "Respiration.BreathingFrequency",
        "short": "BreathingFrequency",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Ademfrequentie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The value of the measured breathing frequency. The breathing frequency is the number of breaths per minute.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De waarde van de gemeten ademhalingsfrequentie. De ademhalingsfrequentie betreft het aantal ademhalingen per minuut."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.BreathingFrequency",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "qty-3",
            "severity": "error",
            "human": "If a code for the unit is present, the system SHALL also be present",
            "expression": "code.empty() or system.exists()",
            "xpath": "not(exists(f:code)) or exists(f:system)",
            "source": "http://hl7.org/fhir/StructureDefinition/Quantity"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "SN (see also Range) or CQ"
          },
          {
            "identity": "rim",
            "map": "PQ, IVL<PQ>, MO, CO, depending on the values"
          }
        ]
      },
      {
        "id": "Respiration.BreathingDateTime",
        "path": "Respiration.BreathingDateTime",
        "short": "BreathingDateTime",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "AdemhalingDatumTijd"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Date and if possible time of measurement.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Datum en eventueel tijd van de meting."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 1,
        "max": "1",
        "base": {
          "path": "Respiration.BreathingDateTime",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.Rhythm",
        "path": "Respiration.Rhythm",
        "short": "Rhythm",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Ritme"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The rhythm or regularity of breathing.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Het ritme of de regelmaat van de ademhaling."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.Rhythm",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "Rhythm codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/Ritme"
        },
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "CE/CNE/CWE"
          },
          {
            "identity": "rim",
            "map": "CD"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept rdfs:subClassOf dt:CD"
          }
        ]
      },
      {
        "id": "Respiration.Depth",
        "path": "Respiration.Depth",
        "short": "Depth",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Diepte"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The depth of the breaths.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De diepte van de ademteugen."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.Depth",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "Depth codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/Diepte"
        },
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "CE/CNE/CWE"
          },
          {
            "identity": "rim",
            "map": "CD"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept rdfs:subClassOf dt:CD"
          }
        ]
      },
      {
        "id": "Respiration.DeviatingBreathingPattern",
        "path": "Respiration.DeviatingBreathingPattern",
        "short": "DeviatingBreathingPattern",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "AfwijkendAdemhalingspatroon"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Specific, abnormal breathing patterns.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Specifieke, abnormale ademhalingspatronen."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.DeviatingBreathingPattern",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "DeviatingBreathingPattern codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/AfwijkendAdemhalingspatroon"
        },
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "CE/CNE/CWE"
          },
          {
            "identity": "rim",
            "map": "CD"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept rdfs:subClassOf dt:CD"
          }
        ]
      },
      {
        "id": "Respiration.ExtraOxygenAdministration",
        "path": "Respiration.ExtraOxygenAdministration",
        "short": "ExtraOxygenAdministration",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ExtraZuurstofToediening"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "An indication stating whether the patient is given extra oxygen. In that event, additional information can be recorded in the concepts that are part of the AdministeredOxygen container.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Een indicatie die aangeeft of de patiënt extra zuurstof toegediend krijgt. Additionele informatie kan in dat geval worden vastgelegd in de concepten die deel uit maken van de container ToegediendeZuurstof."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.ExtraOxygenAdministration",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "boolean"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.Comment",
        "path": "Respiration.Comment",
        "short": "Comment",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Toelichting"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Comment on additional factors that can influence breathing such as the extent of fear, pain, nutrition in the case of infants or a tracheostomy.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Opmerking over bijkomende factoren die de ademhaling kunnen beïnvloeden. Bijvoorbeeld, het niveau van angst, pijn, voeding bij zuigelingen, tracheostomie."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.Comment",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen",
        "path": "Respiration.AdministeredOxygen",
        "short": "AdministeredOxygen",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ToegediendeZuurstof"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Container of the AdministeredOxygen concept. This container contains all data elements of the AdministeredOxygen concept.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Container van het concept ToegediendeZuurstof. Deze container bevat alle gegevenselementen van het concept ToegediendeZuurstof."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.id",
        "path": "Respiration.AdministeredOxygen.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "xml:id (or equivalent in JSON)",
        "definition": "unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.extension",
        "path": "Respiration.AdministeredOxygen.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional Content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.modifierExtension",
        "path": "Respiration.AdministeredOxygen.modifierExtension",
        "short": "Extensions that cannot be ignored",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content",
          "modifiers"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "BackboneElement.modifierExtension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": true,
        "isSummary": true,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.FlowRate",
        "path": "Respiration.AdministeredOxygen.FlowRate",
        "short": "FlowRate",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "FlowRate"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The amount of administered oxygen. The value is between 0.0 and 50.0 l/min.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De hoeveelheid toegediende zuurstof. De waarde ligt tussen 0.0 en 50.0 l/min."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.FlowRate",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "qty-3",
            "severity": "error",
            "human": "If a code for the unit is present, the system SHALL also be present",
            "expression": "code.empty() or system.exists()",
            "xpath": "not(exists(f:code)) or exists(f:system)",
            "source": "http://hl7.org/fhir/StructureDefinition/Quantity"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "SN (see also Range) or CQ"
          },
          {
            "identity": "rim",
            "map": "PQ, IVL<PQ>, MO, CO, depending on the values"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.FiO2",
        "path": "Respiration.AdministeredOxygen.FiO2",
        "short": "FiO2",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "FiO2"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The fractional concentration of inspired oxygen. Value is between 0.0 and 1.0, with a normal value of 0.21 (no extra oxygen administered).",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De fractionele inspiratoire zuurstof concentratie. Waarde ligt tussen 0.0 en 1.0, met een normale waarde van 0.21 (geen extra zuurstoftoediening)."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.FiO2",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "qty-3",
            "severity": "error",
            "human": "If a code for the unit is present, the system SHALL also be present",
            "expression": "code.empty() or system.exists()",
            "xpath": "not(exists(f:code)) or exists(f:system)",
            "source": "http://hl7.org/fhir/StructureDefinition/Quantity"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "SN (see also Range) or CQ"
          },
          {
            "identity": "rim",
            "map": "PQ, IVL<PQ>, MO, CO, depending on the values"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice",
        "short": "AdministrationDevice",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ToedieningHulpmiddel"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Device used for administering extra oxygen to the patient.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Hulpmiddel dat gebruikt wordt bij de toediening van extra zuurstof aan de patiënt."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.id",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "xml:id (or equivalent in JSON)",
        "definition": "unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.extension",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional Content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.modifierExtension",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.modifierExtension",
        "short": "Extensions that cannot be ignored",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content",
          "modifiers"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "BackboneElement.modifierExtension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": true,
        "isSummary": true,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice",
        "short": "MedicalDevice",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "MedischHulpmiddel"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Root concept of the MedicalDevice information model. This root concept contains all data elements of the MedicalDevice information model.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Rootconcept van de bouwsteen MedischHulpmiddel. Dit rootconcept bevat alle gegevenselementen van de bouwsteen MedischHulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 1,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.id",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "xml:id (or equivalent in JSON)",
        "definition": "unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.extension",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional Content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.modifierExtension",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.modifierExtension",
        "short": "Extensions that cannot be ignored",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content",
          "modifiers"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "BackboneElement.modifierExtension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": true,
        "isSummary": true,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product",
        "short": "Product",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Product"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The medical device (internally or externally).",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Het medische hulpmiddel dat wordt gebruikt (inwendig of uitwendig)."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 1,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.id",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "xml:id (or equivalent in JSON)",
        "definition": "unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.extension",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional Content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.modifierExtension",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.modifierExtension",
        "short": "Extensions that cannot be ignored",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content",
          "modifiers"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "BackboneElement.modifierExtension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": true,
        "isSummary": true,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductId",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductId",
        "short": "ProductID",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ProductID"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Unique identification of the product, such as the serial number. \r\nFrequently used coding systems are HIBC and GTIN.\r\nIf the law requires this to be registered on the basis of a UDI (Unique Device Identifier), the unique identification must consist of a UDI-DI (Device Identifier) and a UDI-PI (Production Identifier(s)). See http://www.gs1.org/healthcare/udi for more information. \r\n\r\nThe UDI-DI must be recorded in reference to GS1 GTIN (01) encryptions, with which for example a firm is linked to the product type. The UDI-PI must consist of the following: application identifier (AI); expiration date (17) and serial number (21) and/or batch or lot number (10).",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Unieke identificatie van het product, bijvoorbeeld het serienummer.\r\nVeel gebruikte coderingen zijn HIBC en GTIN.\r\nIndien de wet verplicht stelt dat deze geregistreerd wordt op basis van een UDI (Unique Device Identifier), dient de unieke identificatie opgebouwd te zijn uit een UDI-DI (Device Identifier) en een UDI-PI (Production Identifier(s)). Voor meer informatie, zie: http://www.gs1.org/healthcare/udi .\r\n\r\nDe UDI-DI dient m.b.t. GS1 GTIN (01) coderingen worden vastgelegd, waarmee o.a. een firma aan het producttype wordt gekoppeld. De UDI-PI dient te bestaan uit de volgende application identifier (AI); vervaldatum (17) en serienummer (21) en/of batch- of lotnummer (10)."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductId",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "CE/CNE/CWE"
          },
          {
            "identity": "rim",
            "map": "CD"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept rdfs:subClassOf dt:CD"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductType",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductType",
        "short": "ProductType",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ProductType"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Type of device used for administering.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Type toedieningshulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductType",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "ProductType codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/ToedieningHulpmiddel"
        },
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "v2",
            "map": "CE/CNE/CWE"
          },
          {
            "identity": "rim",
            "map": "CD"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept rdfs:subClassOf dt:CD"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.ProductDescription",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.ProductDescription",
        "short": "ProductDescription",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ProductOmschrijving"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Textual description of the product.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Tekstuele beschrijving van het product."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.ProductDescription",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.AnatomicalLocation",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.AnatomicalLocation",
        "short": "AnatomicalLocation",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "AnatomischeLocatie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Patient’s anatomical location of the medical device used.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Anatomische locatie van het gebruikte hulpmiddel bij de patiënt."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.AnatomicalLocation",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-AnatomicalLocation"
            ]
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ref-1",
            "severity": "error",
            "human": "SHALL have a contained resource if a local reference is provided",
            "expression": "reference.startsWith('#').not() or (reference.substring(1).trace('url') in %resource.contained.id.trace('ids'))",
            "xpath": "not(starts-with(f:reference/@value, '#')) or exists(ancestor::*[self::f:entry or self::f:parameter]/f:resource/f:*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')]|/*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Reference"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "The target of a resource reference is a RIM entry point (Act, Role, or Entity)"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Indication",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Indication",
        "short": "Indication",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Indicatie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The medical reason for use of the medical device.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De medische reden voor het gebruik van het medisch hulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Indication",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-Problem"
            ]
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ref-1",
            "severity": "error",
            "human": "SHALL have a contained resource if a local reference is provided",
            "expression": "reference.startsWith('#').not() or (reference.substring(1).trace('url') in %resource.contained.id.trace('ids'))",
            "xpath": "not(starts-with(f:reference/@value, '#')) or exists(ancestor::*[self::f:entry or self::f:parameter]/f:resource/f:*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')]|/*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Reference"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "The target of a resource reference is a RIM entry point (Act, Role, or Entity)"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.StartDate",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.StartDate",
        "short": "StartDate",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "BeginDatum"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The start date of the first use or implant of the medical device. A ‘vague’ date, such as only the year, is permitted.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De startdatum van eerste toepassing of implantatie het medische hulpmiddel. Een vage datum, bijv. alleen een jaartal, is toegestaan."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.StartDate",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.EindDatum",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.EindDatum",
        "short": "EindDatum",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "EindDatum"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The end date of the last use or explant of the medical device. A ‘vague’ date, such as only the year, is permitted.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De einddatum van de laatste toepassing of explantatie van het medische hulpmiddel. Een vage datum, bijv. alleen een jaartal, is toegestaan."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "alias": [
          "EndDate"
        ],
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.EindDatum",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Comment",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Comment",
        "short": "Comment",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Toelichting"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Comment about use or information on the medical device used.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Opmerking bij de toepassing of informatie over het gebruikte hulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "Note that FHIR strings may not exceed 1MB in size",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Comment",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Location",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Location",
        "short": "Location",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Locatie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The healthcare organization at which use of the medical device was initiated or where the aid was implanted.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De zorgaanbieder waar het gebruik van het hulpmiddel geïnitieerd werd of waar het hulpmiddel geïmplanteerd werd."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Location",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-HealthcareOrganization"
            ]
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ref-1",
            "severity": "error",
            "human": "SHALL have a contained resource if a local reference is provided",
            "expression": "reference.startsWith('#').not() or (reference.substring(1).trace('url') in %resource.contained.id.trace('ids'))",
            "xpath": "not(starts-with(f:reference/@value, '#')) or exists(ancestor::*[self::f:entry or self::f:parameter]/f:resource/f:*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')]|/*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Reference"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "The target of a resource reference is a RIM entry point (Act, Role, or Entity)"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.HealthProfessional",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.HealthProfessional",
        "short": "HealthProfessional",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Zorgverlener"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The healthcare professional involved in the indication for use of the medical device implant.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De zorgverlener betrokken bij de indicatiestelling voor het gebruik of de implantatie van het hulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "comment": "References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.HealthProfessional",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-HealthProfessional"
            ]
          }
        ],
        "condition": [
          "ele-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() | (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ref-1",
            "severity": "error",
            "human": "SHALL have a contained resource if a local reference is provided",
            "expression": "reference.startsWith('#').not() or (reference.substring(1).trace('url') in %resource.contained.id.trace('ids'))",
            "xpath": "not(starts-with(f:reference/@value, '#')) or exists(ancestor::*[self::f:entry or self::f:parameter]/f:resource/f:*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')]|/*/f:contained/f:*[f:id/@value=substring-after(current()/f:reference/@value, '#')])",
            "source": "http://hl7.org/fhir/StructureDefinition/Reference"
          }
        ],
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          },
          {
            "identity": "rim",
            "map": "The target of a resource reference is a RIM entry point (Act, Role, or Entity)"
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "Respiration",
        "path": "Respiration",
        "short": "Respiration",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Ademhaling"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Root concept of the Breathing information model. This root concept contains all data elements of the Breathing information model.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Rootconcept van de bouwsteen Ademhaling. Dit rootconcept bevat alle gegevenselementen van de bouwsteen Ademhaling."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "*"
      },
      {
        "id": "Respiration.BreathingFrequency",
        "path": "Respiration.BreathingFrequency",
        "short": "BreathingFrequency",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Ademfrequentie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The value of the measured breathing frequency. The breathing frequency is the number of breaths per minute.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De waarde van de gemeten ademhalingsfrequentie. De ademhalingsfrequentie betreft het aantal ademhalingen per minuut."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Quantity"
          }
        ]
      },
      {
        "id": "Respiration.BreathingDateTime",
        "path": "Respiration.BreathingDateTime",
        "short": "BreathingDateTime",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "AdemhalingDatumTijd"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Date and if possible time of measurement.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Datum en eventueel tijd van de meting."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "Respiration.Rhythm",
        "path": "Respiration.Rhythm",
        "short": "Rhythm",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Ritme"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The rhythm or regularity of breathing.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Het ritme of de regelmaat van de ademhaling."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "Rhythm codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/Ritme"
        }
      },
      {
        "id": "Respiration.Depth",
        "path": "Respiration.Depth",
        "short": "Depth",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Diepte"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The depth of the breaths.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De diepte van de ademteugen."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "Depth codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/Diepte"
        }
      },
      {
        "id": "Respiration.DeviatingBreathingPattern",
        "path": "Respiration.DeviatingBreathingPattern",
        "short": "DeviatingBreathingPattern",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "AfwijkendAdemhalingspatroon"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Specific, abnormal breathing patterns.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Specifieke, abnormale ademhalingspatronen."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "DeviatingBreathingPattern codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/AfwijkendAdemhalingspatroon"
        }
      },
      {
        "id": "Respiration.ExtraOxygenAdministration",
        "path": "Respiration.ExtraOxygenAdministration",
        "short": "ExtraOxygenAdministration",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ExtraZuurstofToediening"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "An indication stating whether the patient is given extra oxygen. In that event, additional information can be recorded in the concepts that are part of the AdministeredOxygen container.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Een indicatie die aangeeft of de patiënt extra zuurstof toegediend krijgt. Additionele informatie kan in dat geval worden vastgelegd in de concepten die deel uit maken van de container ToegediendeZuurstof."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "boolean"
          }
        ]
      },
      {
        "id": "Respiration.Comment",
        "path": "Respiration.Comment",
        "short": "Comment",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Toelichting"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Comment on additional factors that can influence breathing such as the extent of fear, pain, nutrition in the case of infants or a tracheostomy.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Opmerking over bijkomende factoren die de ademhaling kunnen beïnvloeden. Bijvoorbeeld, het niveau van angst, pijn, voeding bij zuigelingen, tracheostomie."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen",
        "path": "Respiration.AdministeredOxygen",
        "short": "AdministeredOxygen",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ToegediendeZuurstof"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Container of the AdministeredOxygen concept. This container contains all data elements of the AdministeredOxygen concept.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Container van het concept ToegediendeZuurstof. Deze container bevat alle gegevenselementen van het concept ToegediendeZuurstof."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "BackboneElement"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.FlowRate",
        "path": "Respiration.AdministeredOxygen.FlowRate",
        "short": "FlowRate",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "FlowRate"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The amount of administered oxygen. The value is between 0.0 and 50.0 l/min.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De hoeveelheid toegediende zuurstof. De waarde ligt tussen 0.0 en 50.0 l/min."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Quantity"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.FiO2",
        "path": "Respiration.AdministeredOxygen.FiO2",
        "short": "FiO2",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "FiO2"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The fractional concentration of inspired oxygen. Value is between 0.0 and 1.0, with a normal value of 0.21 (no extra oxygen administered).",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De fractionele inspiratoire zuurstof concentratie. Waarde ligt tussen 0.0 en 1.0, met een normale waarde van 0.21 (geen extra zuurstoftoediening)."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Quantity"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice",
        "short": "AdministrationDevice",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ToedieningHulpmiddel"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Device used for administering extra oxygen to the patient.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Hulpmiddel dat gebruikt wordt bij de toediening van extra zuurstof aan de patiënt."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "BackboneElement"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice",
        "short": "MedicalDevice",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "MedischHulpmiddel"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Root concept of the MedicalDevice information model. This root concept contains all data elements of the MedicalDevice information model.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Rootconcept van de bouwsteen MedischHulpmiddel. Dit rootconcept bevat alle gegevenselementen van de bouwsteen MedischHulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "BackboneElement"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product",
        "short": "Product",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Product"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The medical device (internally or externally).",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Het medische hulpmiddel dat wordt gebruikt (inwendig of uitwendig)."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "BackboneElement"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductId",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductId",
        "short": "ProductID",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ProductID"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Unique identification of the product, such as the serial number. \r\nFrequently used coding systems are HIBC and GTIN.\r\nIf the law requires this to be registered on the basis of a UDI (Unique Device Identifier), the unique identification must consist of a UDI-DI (Device Identifier) and a UDI-PI (Production Identifier(s)). See http://www.gs1.org/healthcare/udi for more information. \r\n\r\nThe UDI-DI must be recorded in reference to GS1 GTIN (01) encryptions, with which for example a firm is linked to the product type. The UDI-PI must consist of the following: application identifier (AI); expiration date (17) and serial number (21) and/or batch or lot number (10).",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Unieke identificatie van het product, bijvoorbeeld het serienummer.\r\nVeel gebruikte coderingen zijn HIBC en GTIN.\r\nIndien de wet verplicht stelt dat deze geregistreerd wordt op basis van een UDI (Unique Device Identifier), dient de unieke identificatie opgebouwd te zijn uit een UDI-DI (Device Identifier) en een UDI-PI (Production Identifier(s)). Voor meer informatie, zie: http://www.gs1.org/healthcare/udi .\r\n\r\nDe UDI-DI dient m.b.t. GS1 GTIN (01) coderingen worden vastgelegd, waarmee o.a. een firma aan het producttype wordt gekoppeld. De UDI-PI dient te bestaan uit de volgende application identifier (AI); vervaldatum (17) en serienummer (21) en/of batch- of lotnummer (10)."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductType",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Product.ProductType",
        "short": "ProductType",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ProductType"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Type of device used for administering.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Type toedieningshulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "extensible",
          "description": "ProductType codes",
          "valueSet": "https://fhir.healthdata.be/ValueSet/ToedieningHulpmiddel"
        }
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.ProductDescription",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.ProductDescription",
        "short": "ProductDescription",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "ProductOmschrijving"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Textual description of the product.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Tekstuele beschrijving van het product."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.AnatomicalLocation",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.AnatomicalLocation",
        "short": "AnatomicalLocation",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "AnatomischeLocatie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Patient’s anatomical location of the medical device used.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Anatomische locatie van het gebruikte hulpmiddel bij de patiënt."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-AnatomicalLocation"
            ]
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Indication",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Indication",
        "short": "Indication",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Indicatie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The medical reason for use of the medical device.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De medische reden voor het gebruik van het medisch hulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-Problem"
            ]
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.StartDate",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.StartDate",
        "short": "StartDate",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "BeginDatum"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The start date of the first use or implant of the medical device. A ‘vague’ date, such as only the year, is permitted.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De startdatum van eerste toepassing of implantatie het medische hulpmiddel. Een vage datum, bijv. alleen een jaartal, is toegestaan."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.EindDatum",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.EindDatum",
        "short": "EindDatum",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "EindDatum"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The end date of the last use or explant of the medical device. A ‘vague’ date, such as only the year, is permitted.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De einddatum van de laatste toepassing of explantatie van het medische hulpmiddel. Een vage datum, bijv. alleen een jaartal, is toegestaan."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "alias": [
          "EndDate"
        ],
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Comment",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Comment",
        "short": "Comment",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Toelichting"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "Comment about use or information on the medical device used.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Opmerking bij de toepassing of informatie over het gebruikte hulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Location",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.Location",
        "short": "Location",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Locatie"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The healthcare organization at which use of the medical device was initiated or where the aid was implanted.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De zorgaanbieder waar het gebruik van het hulpmiddel geïnitieerd werd of waar het hulpmiddel geïmplanteerd werd."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-HealthcareOrganization"
            ]
          }
        ]
      },
      {
        "id": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.HealthProfessional",
        "path": "Respiration.AdministeredOxygen.AdministrationDevice.MedicalDevice.HealthProfessional",
        "short": "HealthProfessional",
        "_short": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "Zorgverlener"
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "definition": "The healthcare professional involved in the indication for use of the medical device implant.",
        "_definition": {
          "extension": [
            {
              "extension": [
                {
                  "url": "lang",
                  "valueCode": "nl-NL"
                },
                {
                  "url": "content",
                  "valueMarkdown": "De zorgverlener betrokken bij de indicatiestelling voor het gebruik of de implantatie van het hulpmiddel."
                }
              ],
              "url": "http://hl7.org/fhir/StructureDefinition/translation"
            }
          ]
        },
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-HealthProfessional"
            ]
          }
        ]
      }
    ]
  }
}