<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="HdBe-HearingFunction.HearingAid.Product" />
  <url value="https://fhir.healthdata.be/StructureDefinition/HdBe-HearingFunction.HearingAid.Product" />
  <name value="HdBeHearingFunctionHearingAidProduct" />
  <title value="HdBe HearingFunction.HearingAid.Product" />
  <status value="draft" />
  <date value="2022-10-17T09:09:13.9562003+00:00" />
  <publisher value="Healthdata.be (Sciensano)" />
  <contact>
    <name value="Service portal – healthdata.be" />
    <telecom>
      <system value="url" />
      <value value="https://sciensano.service-now.com/sp" />
      <use value="work" />
    </telecom>
  </contact>
  <description value="The (type of) product used to help the patient hear." />
  <copyright value="Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise." />
  <fhirVersion value="4.0.1" />
  <mapping>
    <identity value="zib-hearingfunction-v3.2-2020EN" />
    <uri value="https://zibs.nl/wiki/HearingFunction-v3.2(2020EN)" />
    <name value="zib HearingFunction-v3.2(2020EN)" />
  </mapping>
  <mapping>
    <identity value="HdBe-HearingFunction" />
    <uri value="https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-HearingFunction" />
    <name value="HdBe logical model HearingFunction" />
  </mapping>
  <kind value="resource" />
  <abstract value="false" />
  <type value="Device" />
  <baseDefinition value="https://fhir.healthdata.be/StructureDefinition/HdBe-MedicalDevice.Product" />
  <derivation value="constraint" />
  <differential>
    <element id="Device">
      <path value="Device" />
      <comment value="This is a specialization of the [HdBe-MedicalDevice.Product](https://fhir.healthdata.be/StructureDefinition/HdBe-MedicalDevice.Product) profile to represent HearingAid devices within the context of HdBe-HearingFunction." />
    </element>
    <element id="Device.type">
      <path value="Device.type" />
      <definition value="The type of product used to help the patient hear." />
      <binding>
        <strength value="extensible" />
        <valueSet value="https://fhir.healthdata.be/ValueSet/HearingAidType" />
      </binding>
      <mapping>
        <identity value="zib-hearingfunction-v3.2-2020EN" />
        <map value="NL-CM:10.1.3" />
        <comment value="ProductType" />
      </mapping>
      <mapping>
        <identity value="HdBe-HearingFunction" />
        <map value="HearingFunction.HearingAid.MedicalDevice.Product.ProductType" />
      </mapping>
    </element>
  </differential>
</StructureDefinition>