<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="observation-de-vitalsign-blutdruck" />
  <url value="http://fhir.de/StructureDefinition/observation-de-vitalsign-blutdruck" />
  <version value="1.6.0-ballot" />
  <name value="VitalSignDE_Blutdruck" />
  <title value="Observation-Profil Blutdruck" />
  <status value="active" />
  <experimental value="false" />
  <date value="2025-12-23" />
  <publisher value="HL7 Deutschland e.V. (Technisches Komitee FHIR)" />
  <contact>
    <telecom>
      <system value="url" />
      <value value="http://hl7.de/technische-komitees/fhir/" />
    </telecom>
  </contact>
  <description value="Observation-Profil Blutdruck" />
  <fhirVersion value="4.0.1" />
  <kind value="resource" />
  <abstract value="false" />
  <type value="Observation" />
  <baseDefinition value="http://fhir.de/StructureDefinition/observation-de-vitalsign" />
  <derivation value="constraint" />
  <differential>
    <element id="Observation.code.coding">
      <path value="Observation.code.coding" />
      <slicing>
        <discriminator>
          <type value="pattern" />
          <path value="$this" />
        </discriminator>
        <rules value="open" />
      </slicing>
    </element>
    <element id="Observation.code.coding:loinc">
      <path value="Observation.code.coding" />
      <sliceName value="loinc" />
      <min value="1" />
      <max value="1" />
      <patternCoding>
        <system value="http://loinc.org" />
        <code value="85354-9" />
      </patternCoding>
    </element>
    <element id="Observation.code.coding:snomed">
      <path value="Observation.code.coding" />
      <sliceName value="snomed" />
      <min value="0" />
      <max value="*" />
      <patternCoding>
        <system value="http://snomed.info/sct" />
        <code value="75367002" />
      </patternCoding>
    </element>
    <element id="Observation.value[x]">
      <path value="Observation.value[x]" />
      <max value="0" />
    </element>
    <element id="Observation.value[x]:valueQuantity">
      <path value="Observation.value[x]" />
      <sliceName value="valueQuantity" />
      <max value="0" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component">
      <path value="Observation.component" />
      <slicing>
        <discriminator>
          <type value="pattern" />
          <path value="code" />
        </discriminator>
        <rules value="open" />
      </slicing>
      <min value="2" />
    </element>
    <element id="Observation.component:SystolicBP">
      <path value="Observation.component" />
      <sliceName value="SystolicBP" />
      <min value="1" />
      <max value="1" />
    </element>
    <element id="Observation.component:SystolicBP.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://loinc.org" />
          <code value="8480-6" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:SystolicBP.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:SystolicBP.value[x]:valueQuantity">
      <path value="Observation.component.value[x]" />
      <sliceName value="valueQuantity" />
      <type>
        <code value="Quantity" />
      </type>
      <patternQuantity>
        <system value="http://unitsofmeasure.org" />
        <code value="mm[Hg]" />
      </patternQuantity>
    </element>
    <element id="Observation.component:DiastolicBP">
      <path value="Observation.component" />
      <sliceName value="DiastolicBP" />
      <min value="1" />
      <max value="1" />
    </element>
    <element id="Observation.component:DiastolicBP.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://loinc.org" />
          <code value="8462-4" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:DiastolicBP.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:DiastolicBP.value[x]:valueQuantity">
      <path value="Observation.component.value[x]" />
      <sliceName value="valueQuantity" />
      <type>
        <code value="Quantity" />
      </type>
      <patternQuantity>
        <system value="http://unitsofmeasure.org" />
        <code value="mm[Hg]" />
      </patternQuantity>
    </element>
    <element id="Observation.component:meanBP">
      <path value="Observation.component" />
      <sliceName value="meanBP" />
      <min value="0" />
      <max value="1" />
    </element>
    <element id="Observation.component:meanBP.code">
      <path value="Observation.component.code" />
      <patternCodeableConcept>
        <coding>
          <system value="http://loinc.org" />
          <code value="8478-0" />
        </coding>
      </patternCodeableConcept>
    </element>
    <element id="Observation.component:meanBP.value[x]">
      <path value="Observation.component.value[x]" />
      <type>
        <code value="Quantity" />
      </type>
    </element>
    <element id="Observation.component:meanBP.value[x]:valueQuantity">
      <path value="Observation.component.value[x]" />
      <sliceName value="valueQuantity" />
      <type>
        <code value="Quantity" />
      </type>
      <patternQuantity>
        <system value="http://unitsofmeasure.org" />
        <code value="mm[Hg]" />
      </patternQuantity>
    </element>
  </differential>
</StructureDefinition>